Filter Results By:

Products

Applications

Manufacturers

Test Systems

group of interoperable devices whose integration perform a common test purpose.

See Also: Systems, Equipment, System Integrators, System Test, System Integration


Showing results: 3121 - 3135 of 5363 items found.

  • PXI-2556, 2.5 GHz, 75 Ω, Dual 4x1 PXI RF Multiplexer Switch Module

    778572-56 - NI

    2.5 GHz, 75 Ω, Dual 4x1 PXI RF Multiplexer Switch Module—The PXI‑2556 is an RF signal multiplexer switch module. The multi-bank architecture of the NI PXI‑2556 makes it ideal for test systems that require parallel operations such as the stimulus/response testing of video RF devices such as tuners. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-02 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module

    785185-01 - NI

    16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.

  • Quadruple Function Tester with Shielded HF Test Chambers

    UTP 9011 RF - NOFFZ Computer Technik GmbH

    Circuit boards are the heart of all electronic devices. To ensure the reliable function of these boards, detailed tests are essential.Our board-level tester UTP 9011 RF works safely, quickly and cost-optimized at circuit board level. Our interchangeable adapters are particularly efficient in this system, with which you can even test different test items at the same time. The shielded NOFFZ HF test chamber always ensures consistently good results.

  • Drop Weight Impact Testing Machine

    DWTT Series - Jinan Testing Equipment IE Corporation

    DWTT Drop Weight Impact Testing System is suitable for drop weight tear test of various kinds of ferrite, especially for the test of DWTT for pipeline steel as ASTM-E 436, API-RP 5L3, ASTM-E 208 and DIN EN 10274. DWTT has integrated mechanical, electrical, and automatic control technology, and achieved full automation of feeding, hammer lifting impact, and fracture specimen collection. The load frame has a four-column design, features in stable supporting structure, rigid, dual sliding rails. The Drop Weight Drop Weight Tester is equipped with positioning mechanism, anti-dumping mechanism, safety mechanism, hydraulic buffer devices and security guard net. The impact energy is determined by the lifting height and configuration of different net weights. DWTT Drop Weight Impact Testing System is the essential quality control equipment for pipeline manufacturers, steel mills, iron and steel enterprises, and is also widely used for research institutes.1. Buffer device is equipped to avoid the second impact and absorb the residual energy after breaking the specimen so as to prevent the weigher and anvil from destroying. The installation of safety mechanism, buffer device, and security guard net will effectively secure the testing machine and its operation to extend its life.2. Configuration of the specimen-feeding system, anti-second impact device, and specimen centering mechanism will guarantee a quick, accurate and reliable test.

  • Wafer Probing Machine

    UF3000EX-e - CSE Co.,Ltd

    Wafer Probe Station is used in connection with test system in Wafer Test process.It is a device to move wafer automatically to examine fair quality of individual chip on the wafer. Probe Station is seperated depending on purpose. For analysis, for mass production as well as manual, semi-automatic, full-automatic.

  • AC DC Test Equipment

    Hilo Test

    The products impress with a variety of technical features: TFT display, Ethernet interface, automatic test sequence to a fully electronic generator for even faster and more accurate tests. Our safety testers can be used both stand-alone without a PC as well as integrate with existing systems.

  • NI Automated Test Software Suite

    NI

    The NI Automated Test Software Suite features all three NI IDEs and NI's most popular application software and add-ons specifically for building your automated test system with confidence. This package offers the power of LabVIEW, LabWindows/CVI, and Measurement Studio combined with the TestStand ready-to-run, test executive and the Switch Executive intelligent switch management application

  • Moving Die Rheometer

    SG-S05A - Jinge Testing Machine Co.,Ltd

    It tests the feature about vulcanization and searches for the best suitable vulcanization time.It adopts digital intelligent temperature-controller to adjust and sets easily.Its stability, reappear and accuracy is better than the general rotor rheometer.The microcomputer uses import CMOS chip which has high dependability.It draws、calculates and prints automatically,and has copy or blowwing up function. It adopts computer-control and interface to collect、store or deal with data and print test result .This machine's function is better than other types and shows high automatization features. It has functions about curve-comparing and blow up.It uses series of windows operation system flat and graphical software operation interface.The data is dealed with much truly.The user's test operation becomes faster, flexibly and protect conveniently.

  • 12V Automatic Battery and 12/24V Electrical System Analyzer

    6044 - Associated Equipment Corp.

    • Easy-to-read LED voltmeter and ammeter• 500 amp safety clamps with “Flexi-Spring” and patented side terminal adapters• Separate 6 ft. high impedance test leads with alligator clips for tight spots• Cart / Printer can be purchased separately – Cart Model 6038C, Printer Model 6041• Automated testing of Batteries, Alternators, & Starters• Max/Min of Current and Voltage• Microprocessor based control board protected from reverse connections• Testing of 12V and 24V electrical systems• Test all types of batteries • Ideal for testing remotely mounted batteries accurately• Automated 500A variable load tester• INCLUDES: Model 6043 1000 Amp AC/DC Inductive Amp Clamp for checking starter draw or parasitic drain test, also can be used with conventional multi-meters• Made in USA of US and Global Components

  • Full Band Noise Figure and Gain Test Extenders

    STG-06-S1 - ERAVANT

    Full band noise figure and gain test extenders are offered to extend noise and gain measuring capabilities up to higher millimeterwave frequency ranges. These extenders are designed to interface with noise and gain test systems that have an input IF of 10 MHz to 1.6 GHz, such as the industry standard Keysight 8970A/B, N8975A and Maury MT 2075B. The noise figure and gain test extenders include a high-performance, solid-state noise source (STZ series) and a full waveguide down converter (STC series), which consists of a Faraday isolator (STF series), full band mixer (SFB series), frequency multiplier, and IF amplifier. A frequency source with an output signal in the frequency range of 10 to 20 GHz is required as a local oscillator for the down converter. The noise source is automatically powered on and off by the noise figure meter.

  • Wire Test Unit

    McGan Technology

    The Wire Testing Unit (WTU) is used in conjunction with the MMPD-8K kit or the MM5KV Kit purchased with the optional HV Red Wire and is used to easily test the continuity of electrosurgical cables used to connect the electrosurgical generator either to the active handpiece (e.g. laparoscopic instruments or forceps) or to the return electrode which completes the circuit between the generator and the patient. If the conductor is broken without damage to the cable’s jacket it can remain unseen and could be put into use for the electrosurgical operation causing the system to not properly function. By using the WTU you can test to ensure that the cables have continuity prior to actual usage in the operating room. This does not preclude the other tests that should be performed on these cables such as visually examining the cable for jacket damage including cracks, pinholes and abrasions and manually flexing the cable.

  • Dynamic Digital I/O With Per Channel Timing, Programmable Logic Levels And PMU PXI Card

    GX5296 - Marvin Test Solutions, Inc.

    The GX5296 offers advanced dynamic digital I/O performance and capabilities in a single slot, 3U PXI format. The 32-channel, GX5296 features timing per pin, multiple time sets, data formatting, and an advanced sequencer – providing users with the capability to emulate and test complex digital busses for system, board or device test applications. Offering sub-nanosecond edge placement resolution per pin and a PMU per pin, the GX5296 has the ability to perform both DC and AC parametric testing. Each digital channel can be individually programmed for a drive hi, drive lo, sense hi, sense lo, and load value (with commutation voltage level). In addition, each channel offers a parametric measurement unit (PMU) providing users with the capability to perform parallel DC measurements on the DUT (device under test).

  • Dissolution Media Prep System

    Media-Mate Plus - Teledyne LABS

    The Media-Mate Plus™ is the perfect media-prep system for a busy dissolution lab that demands both speed and accuracy. It delivers pre-heated, filtered, deaerated, and volumetrically dispensed media to 6 or 7 dissolution vessels simultaneously in less than five minutes. Built on a unique ergonomic cart, the Media-Mate Plus offers maximum portability for easy servicing of many dissolution test stations.The Media-Mate Plus exceeds USP / US FDA recommended media deaeration specifications making it one of the most effective tools in ensuring successful Performance Verification Tests (PVT). By significantly reducing dissolved oxygen levels and dispensing media simultaneously into 6 or 7 vessels, the MediaMate Plus eliminates the variable caused by Prednisone tablets that are highly sensitive to dissolved oxygen levels, thus facilitating successful passage of PVT tests.

  • Fracture Mechanics Clip-On Gages

    Model 3541 - Jinan Testing Equipment IE Corporation

    The Model 3541 is designed for determination of fracture mechanics parameters such as JIC, KIC, R-curve, fatigue crack growth rate (da/dN), and testing to standards such as E1820, E399, E647, etc. These COD gages conform to the requirements of E1820 (the replacement for E813 and E1737) for JIC and R-curve determination. Special configurations are available to meet the requirements of ASTM E399 for fracture toughness (please consult the factory for these configurations). In addition, the modified groove design complies with E1820 tests where greater stability and accuracy results from the sharper groove root. Clip-on gages are used for a variety of fracture mechanics tests, including compact tension, arc shaped, disk shaped, bend specimens or other specimen geometries in compliance with ASTM and other standards organization’s test methods. Clip-on gages can be used directly on test specimens where the knife edges are integral with the test specimen or, alternately, with optional bolt-on knife edges mounted on the test specimen.The Model 3541 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.